Description Specification Downloads Description Pump body, motor support and impeller in brass. Carbon/ceramic mechanical seal. Stainless steel motor shaft. Asynchronous, closed motor cooled by external ventilation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life. Motor overload cut out equipped as standard in the singlephase version. Overload protection to be provided by the user for the three-phase version. Permanently connected capacitor for the single-phase version. Construction to CEI 2-3 and CEI 61-69 (EN 60335-2-41) Features Protection rating: IP 44 Insulation class: F Standard voltage: 1x230V 50Hz single-phase 3x230-400V 50Hz three-phase Operating range: from 1 to 35 l/min with head up to 107 meters. Pumped liquid: clean, free from solids or abrasive substances, not aggressive. Liquid temperature range: - from 0°C to +35°C for domestic use (EN 60335-2-41) - from -10°C to +80°C for other uses. Maximum ambient temperature: +40°C Maximum working pressure: 10 bar (1000 kPa). Installation: fixed in horizontal position.
Description Specification Downloads Description Self-priming peripheral pump with star impeller, with a great suction capacity. Cast iron body with brass ring. Motor support and impeller in brass to avoid the risk of blocking. Driving shaft in stainless steel. Carbon/ceramic mechanical seal. Asynchronous, closed motor, cooled by external ventilation. Built-in thermal and current overload protection and a capacitor permanently on in the single-phase version. For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Features Operating range: from 8 to 45 l/min. with head up to 53 metres. Liquid temperature range: from -10°C to +80°C from 0°C to +35°C for domestic use. Pumped liquid characteristics: clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum ambient temperature: +40°C. Maximum working pressure: 10 bar (1000 kPa). Protection level: IP 44 (IP 55 terminal board protection). Insulation class: F.
Description Specification Downloads Description Peripheral centrifugal pump, reduced encumbrance, able to generate high heads, it is suitable for domestic use and small industrial uses. Pump body and motor support in brass for the KP 60 version, in cast iron for the KPS 30 and KP 38 versions. Brass impeller. Mechanical seal in carbon/ceramic. Asynchronous, closed motor, cooled by external ventilation. Built-in thermal and current overload protection and a capacitor permanently on in the single-phase version. For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Features Operating range: from 1 to 50 l/min. with head up to 107 metres. Liquid temperature range: from 0°C to +35°C for domestic use, from -10°C to +80°C (from -10°C to +50°C for the KPS 30 and KP 38 versions) for other uses. Pumped liquid characteristics: clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum
Description Specification Downloads Description Cast iron discharge and suction bodies treated against corrosion. Technopolymer impellers, diffuser bodies and diffusers. AISI 304 stainless steel pump liner and wear rings. AISI 416 stainless steel pump shaft and AISI 316 stainless steel sliding bush. Bronze sliding bush guide, self-lubricated by the pumped liquid itself. Carbon/ceramic mechanical seal. Connected to the motor with a rigid coupling. Supplied standard with threaded counterflanges. Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealedfor- life ball bearings to ensure silent running and long life. Built-in thermal and current overload protection in the single-phase version. Three-phase motors should be protected with a suitable overload protection complying with the regulations in force. Features Operating range: from 1,8 to 13,5 m3/h with head up to 139 metres. Liquid temperature range: from 0°C to +35°C for domestic use. from -15°C to +110°C for other uses. Liquid quality requirements: clean, free from solids or abrasive substances, non viscous,
Description Specification Downloads Description Vertical multistage centrifugal pump suitable for use in small and medium water supply installations. Suitable for pressurization units, surge tank supply, rain irrigation and crop-dusting systems, fire-fighting and washing systems, conveyance of condensate and cooling water. Innovative and robust design. Technopolymer discharge/suction bodies and in-line suction and discharge ports with threaded metal insert. Impellers, diffuser bodies and diffusers in technopolymer, fully rust-proof. Stainless steel AISI 303 pump jacket, adjustment rings and seal disk. Carbon/ceramic mechanical seal, fitted on the AISI 303 stainless-steel drive shaft extension. Asynchronous, closed motor cooled by external ventilation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently on in the singlephase version. Protection for the three-phase version is the responsibility of the user. Built in CEI 2-3/CEI 61/69 (EN 60335-2-41) standards. Features Level of protection: IP 55. Insulation class: F. Standard voltage: Single-phase 220-240 V /
Description Specification Downloads Description The new MCE/C inverters are the latest technological challenge in the DAB inverters universe. They constitute the new generation of inverters for use with circulator pumps and stand out for ease of use, power, and simplicity of installation and management. MCE/C inverters are designed for use with circulator pumps to enable simple control of differential pressure, thereby adapting pump performance to match effective system requirements. The solution of mounting on the motor base greatly simplifi es installation of the pump with MCE/C in minimal times. Ease of programming is guaranteed by the use of an interface similar to DAB Dialogue and a graphic display. MCE/C inverters feature dual microprocessor architecture to guarantee maximum efficiency and reliability. Sturdy and reliable construction is combined with modern and innovative styling to complete the product also in terms of aesthetics. MCE/C inverters protect the pump thanks to integrated safety devices. They are also able to prolong the useful lifetime of