Description Specification Downloads Description Characterised by the use of multi-impeller vertical axis electric pumps, these sets are acclaimed for their high efficiency, application versatility, and very low noise operation. Utilised in large scale civil and industrial installations, selection of these sets must be performed by skilled engineers capable of assessing the effective requirements of the systems on which they are to be installed. Construction features SETS WITH 2-3 PUMPS. Features HYDRAULIC SECTION 2-3 Multistage vertical electric pumps NKV 10 - NKV 15 NKV 20; Skid in galvanized steel; Flanged suction and discharge manifolds in galvanized steel complete with blank flange; Isolator valves on suction and discharge ports; Check valve for each pump; Radial pressure gauge with isolator valve; Galvanized steel column for mounting of the control panel; Membrane pressure tanks. ELECTRICAL SECTION The pump sets are supplied in a strong carton on a wooden pallet complete with instruction leaflet and wiring diagram.
Description Specification Downloads Description Circulating pumps with in-line connections, suitable for civil and industrial installations for heating, airconditioning and hot water for domestic use. Pump body and motor support in cast iron for ALM 500 and ALP 2000 and in bronze for ALM 200 and ALP 800. Technopolymer impeller and carbon/ceramic mechanical seal. Two-pole, asynchronous motor for the ALP version and four-pole for the ALM version. Built-in thermal and current overload protection and a capacitor permanently on in the single-phase version. Three-phase motors should be protected with a suitable overload protection complying with the regulations in force. Features Operating range: from 0,6 to 8,4 m3/h with head up to 21 metres. Liquid temperature range: from +15°C to +120°C. Pumped liquid characteristics: clean , free from solids or abrasive substances, not viscous, not aggressive, not crystallised, chemically neutral, close to the characteristics of water. Maximum ambient temperature: + 40°C Maximum working pressure: 10 bar (1000 kPa). Protection level: IP 55 Insulation
Description Specification Downloads General Description Automatic water lifting units, suitable for domestic use, small installations for civil, agricultural, industrial use, washing and hobby applications. The unit is equipped with a cast iron bodied self priming pump, vessel, pressure switch for automatic operation, pressure gauge, fitting kit between pump and motor, all pre-assembled. Specification Tank: horizontal, 20 litres capacity type, inner single diaphragm high-grade butyl membrane and virgin polypropylene liner, complete with stands at the bottom and brackets for fixing the pump to the top. Operating range: up to 5.4 m3/h with head up to 61 metres - see tech data Liquid temperature range: from 0°C to +35°C for domestic use from 0°C to +40°C for other use Pumped liquid characteristics: clean, free from solidsor abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum ambient temperature: +40°C Maximum working pressure: 8 bar (800 kPa) Protection level: IP 44 (IP 55 terminal board protection). Insulation class: F. Download Datahseet
Description Specification Downloads Description Circulation pumps with in-line ports, suitable for heating, air conditioning, cooling and domestic hot water systems. Available in single (CM) and twin (DCM) versions Features Three-phase 4-pole asynchronous motor, cooled by external ventilation. Available in single and twin versions Impeller in cast iron or technopolymer Wide range Advantages Flow rates up to 420 m3/h with pressure head of up to 41 metres Possibility of alternating pump operation Different possibilities according to dimensions Widespread coverage of pressure and flow rate requirements Benefits Hydraulic efficiency and top performance Limited wear Flexibility Adaptable to a wide range of applications
Description Specification Downloads Description Circulation pumps with in-line ports, suitable forinstallation in heating and air conditioning, refrigeration,and domestic hot water systems. Extremely versatile thanks to the use of the MCE/Cinverter, they offer performance capable of adaptingautomatically to the system’s various demands whilekeeping pressure differentials unchanged. Available insingle and twin version. PN 16 flanged inlet and delivery mouths, fitted withthreaded holes for pressure gauges. Pump body and support in cast iron, impeller in castiron or technopolymer depending on model (in bronze,on request, only from DN 65 to DN 150). Stainless steel drive shaft. Sealing device: standardised mechanical seal madeto DIN 24960 in carbon / carborundum with O’ ringsin EPDM. 4-pole three-phase indication motor with external cooling. Rotor running on ball bearings, oversized to ensure low noise and durability. Constructed following the CEI 2-3 standards. Features Operating range: from 1.2 to 360 m3/h with head up to 34 meters. Liquid temperature range: -10 °C Õ +130 °C for DN 40 - 50
Description Specification Downloads Description Circulating pumps with in-line connections, suitable for civil and industrial installations for heating, airconditioning and hot water for domestic use. Pump body and motor support in cast iron. PN 16 flanged suction and delivery connections with threaded holes for control pressure gauges. Technopolymer impeller and carbon/ceramic mechanical seal. Three-phase, four-pole, asynchronous motor with external ventilation. To protect the motor it is advisable to use a thermal overload protection complying with the regulations in force. Feature Operating range: from 3,6 to 420 m3/h with head up to 102 metres. Liquid temperature range: from -10°C to +140°C. Pumped liquid characteristics: clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum ambient temperature: +40°C. Maximum working pressure: 16 bar (1600 kPa). Protection level: IP 55. Insulation class: F. PN 16 counter flanges on request.